Polyurethane/PIR Insulated Facade Panel

Composite facade panel with polyurethane/PIR insulation core. Provides thermal insulation

Brochure

Technical Informations

  SPD 1000
Useful Width (mm) 1000
Covering (mm) Painted Galvanized Sheet
(0,30 - 0,40 - 0,50 - 0,60 - 0,70 - 0,80)
Paint Type Polyester
PVdF
Color RAL 9002 a
Texture Corrugated, Microlined, Aluzinc, Magnelis
Insulation Polyurethane / PIR
Insulation Thickness (mm) - h 40 - 50 - 60 - 75 - 80 - 100 - 120
Declared Maximum Thermal Conductivity (W/mK) ≤ 0,023
Reaction to Fire NPD / B-s1, d0

 

a It is the standard color and other colors are manufactured on demand.

 SPD 1000 POLYURETHANE/PIR INSULATED FACADE PANEL


 Multi Support Span (L/200 L=m)





Panel Thickness 

(mm)



Panel weights

(kg/m²)



Distributed Load Bearing (P=kg/m2) 


40 9,3

561 272 208 157 106 80 54
50 9,7

735 366 301 234 168 127 86
60 10,1

893 455 394 311 229 174 119
75 10,7

1197 590 472 375 279 224 169
80 10,9

1316 648 518 414 309 247 185
100   11,7

1557 778 643 516 390 321 251

Renk Skalası

Find Closest Dealer

Panel Joint Detail

Frequently Asked Questions

Izocam Tekiz Products are available at İZOCAM-TEKİZ dealers. We do not offer direct sales.

Product installations are handled by İZOCAM-TEKİZ Installation Dealers.

Products are produced to order. They are not kept in stock. İzofom Panels are kept in stock by retail sales dealers.

The warranty term is 2 years.

TS825 separates our country into 4 Regions. The Insulation Thickness should be calculated based on the required value of Uceiling and Uwall (Heat Permeability Coefficient).

Tekiz website and catalogues show the spring load-bearing capacity for each span. You may use this table to determine the appropriate sheet thickness.

All colours in the RAL Catalogue are available for production provided that a minimum limit is exceeded. The standard sandwich panel/corrugated sheet colour is RAL9002.

Stone wool panels feature high fire resistance. They minimise insurance premiums. They safeguard your investment and prevent the fire from spreading, ensuring safety of your employees at high-risk facilities.

Fire resistance duration for roof sandwich panels. It means that the sandwich panel can bear load, preserve its integrity and maintain its insulation properties for 120 minutes. The important matter to note here is the availability of these three properties (REI120) concurrently.

R : Load-bearing capacity

E : Integrity

I : Insulation

The Regulation on Fire-Proofing Buildings categorise the flammability classes of building materials in line with the fire-reaction classification established with EN 13501-1 Euroclass.


The flammability classes of building materials are A1, A2, B, C, D, E and F.


Smoke and drip classes of the materials are not provided for the classes A1 and F.


Smoke and drip classes of the materials are always provided for the classes A2, B, C and D. For instance: A2-s1,d0 or C-s3,d2.

The term Broof roof plating, which meets all criteria for “External Fire Performance” without running any tests, is used to define the product that makes up the uppermost layer in the roof composition.


There is no need for Broof to be tested for panels where both surfaces are metal.


İzocam-Tekiz Kombi panel and PIR Fibro panel bear the Broof(t2) certification, which means they are resistant to external spread of fire. The (t2) annotation here means that tests were performed in windy conditions.

Fire resistance duration for facade sandwich panels. It means that the sandwich panel preserve
its integrity and maintain its insulation properties for 60 minutes. The important matter to note here is
the availability of these two properties (EI60) concurrently.
E → Integrity
I → Insulation