Casette System Section

They are corrugated roof sheets manufactured for structures with no insulation needs and for the insulation system with on-site installation.

Brochure

Technical Informations

Technical Specifications DK 60 DK 40
Useful Width (mm) 600 400
Rib Height (mm) 100 - 120 - 140 80
Covering (mm) Galvanized Painted Sheet (0,80 - 1,20) Galvanized Painted Sheet (0,70 - 1,20)
Paint Type Polyester
PVdF
Polyester
PVdF
Color RAL 9002a RAL 9002a

 

a It is the standard color and other colors are manufactured on demand.

DK40-8  Multi Support Span (L/200 L=m)
Sheet Thickness
(mm)
Corrugated Weight 
(kg/m2)
3,0 3,5 4,0 4,5 5,0 5,5 6,0
Distributed Load Bearing (P=kg/m2)
0,7 8,66 240 176 135 106 86 71 60
0,8 9,90 274 201 154 122 99 81 68
0,9 11,13 308 226 173 137 111 92 77
1,0 12,37 342 251 192 152 123 102 86
1,2 14,84 411 302 231 182 148 122 103

 

Load bearing values are given according to the galvanized sheet. Panel weights may vary within sheet thickness tolerances.

 

DK60- 10  Multi Support Span (L/200 L=m)
Sheet Thickness
(mm)
Corrugated Weight 
(kg/m2)
3,0 3,5 4,0 4,5 5,0 5,5 6,0
Distributed Load Bearing (P=kg/m2)
0,8 9,63 278 204 156 124 100 83 70
0,9 10,83 314 231 177 140 113 94 79
1,0 12,04 349 257 196 155 126 104 87
1,2 14,44 419 308 236 186 151 125 105

 

Load bearing values are given according to the galvanized sheet. Panel weights may vary within sheet thickness tolerances.

 

DK60- 12  Multi Support Span (L/200 L=m)
Sheet Thickness
(mm)
Corrugated Weight 
(kg/m2)
3,0 3,5 4,0 4,5 5,0 5,5 6,0
Distributed Load Bearing (P=kg/m2)
0,8 10,06 356 262 200 158 128 106 89
0,9 11,31 403 296 227 179 146 120 101
1,0 12,67 448 329 252 199 161 133 112
1,2 15,08 537 395 302 239 193 160 134

 

Load bearing values are given according to the galvanized sheet. Panel weights may vary within sheet thickness tolerances.

 

DK60- 14  Multi Support Span (L/200 L=m)
Sheet Thickness
(mm)
Corrugated Weight 
(kg/m2)
3,0 3,5 4,0 4,5 5,0 5,5 6,0
Distributed Load Bearing (P=kg/m2)
0,8 10,48 443 325 249 197 159 132 111
0,9 11,79 500 368 282 222 180 149 125
1,0 13,10 556 409 313 247 200 165 139
1,2 15,72 667 490 375 297 240 199 167

 

Load bearing values are given according to the galvanized sheet. Panel weights may vary within sheet thickness tolerances.

 

Find Closest Dealer

Panel Joint Detail

Frequently Asked Questions

Izocam Tekiz Products are available at İZOCAM-TEKİZ dealers. We do not offer direct sales.

Product installations are handled by İZOCAM-TEKİZ Installation Dealers.

Products are produced to order. They are not kept in stock. İzofom Panels are kept in stock by retail sales dealers.

The warranty term is 2 years.

TS825 separates our country into 4 Regions. The Insulation Thickness should be calculated based on the required value of Uceiling and Uwall (Heat Permeability Coefficient).

Tekiz website and catalogues show the spring load-bearing capacity for each span. You may use this table to determine the appropriate sheet thickness.

All colours in the RAL Catalogue are available for production provided that a minimum limit is exceeded. The standard sandwich panel/corrugated sheet colour is RAL9002.

Stone wool panels feature high fire resistance. They minimise insurance premiums. They safeguard your investment and prevent the fire from spreading, ensuring safety of your employees at high-risk facilities.

Fire resistance duration for roof sandwich panels. It means that the sandwich panel can bear load, preserve its integrity and maintain its insulation properties for 120 minutes. The important matter to note here is the availability of these three properties (REI120) concurrently.

R : Load-bearing capacity

E : Integrity

I : Insulation

The Regulation on Fire-Proofing Buildings categorise the flammability classes of building materials in line with the fire-reaction classification established with EN 13501-1 Euroclass.


The flammability classes of building materials are A1, A2, B, C, D, E and F.


Smoke and drip classes of the materials are not provided for the classes A1 and F.


Smoke and drip classes of the materials are always provided for the classes A2, B, C and D. For instance: A2-s1,d0 or C-s3,d2.

The term Broof roof plating, which meets all criteria for “External Fire Performance” without running any tests, is used to define the product that makes up the uppermost layer in the roof composition.


There is no need for Broof to be tested for panels where both surfaces are metal.


İzocam-Tekiz Kombi panel and PIR Fibro panel bear the Broof(t2) certification, which means they are resistant to external spread of fire. The (t2) annotation here means that tests were performed in windy conditions.

Fire resistance duration for facade sandwich panels. It means that the sandwich panel preserve
its integrity and maintain its insulation properties for 60 minutes. The important matter to note here is
the availability of these two properties (EI60) concurrently.
E → Integrity
I → Insulation