It is polyurethane insulated roof panel of which top surface is covered with PVC or TPO membrane, and which is manufactured for thermal insulation for roofs with a slope lower than 7%. 

Brochure

Technical Informations

  Fibro Panel
Useful Width (mm) 950 1000
Rib Height (mm) 55 35
Number of Rib (pcs) 4 5
Covering (mm) Painted Galvanized Sheet, Aluzinc, Magnelis
(0,60 - 0,70 - 0,80)
PVC or TPO Membrane (1,20)
Paint Type Polyester
PVdF
Color RAL 9002a
Insulation Stone wool
Insulation Thickness (mm) - h 40 - 50 - 60 - 75 - 80 - 100 - 120
Declared Maximum Thermal Conductivity 10°C (W/mK) ≤ 0,023

Packing quantities according to panel length (pcs)

Thickness(mm) SPÇ 1000 3H  SPÇ 1000 5H SPÇ 950 4H
2.0 ≤ Length (m) ≤ 13,50 
35 14 14 12
40 14 14 12
50 12 12 10
60 10 10 8
75 8 8 8
80 8 8 6
100 6 6 6
 SPÇ 1000 5H FIBRO PANEL Multi Support Span (L/200 L=m)
Panel Thickness  (mm) Panel Weights  (kg/m²) 1,0 1,5 2,0 2,5 3,0 3,5 4,0
    Distributed Load Bearing (P=kg/m2) 
0,6 10,3 554 260 160 105 60 38 26
0,7 11,2 704 325 188 124 71 45 30
0,8 12,1 840 382 212 140 81 51 34
 

 

 

 

SPÇ 950 4H FIBRO PANEL Multi Support Span (L/200 L=m));
Panel Thickness  (mm) Panel Weights (kg/m²) 1,0 1,5 2,0 2,5 3,0 3,5 4,0
    Distributed Load Bearing (P=kg/m2)
0,6 10,5 1014 482 312 211 109 79 49
0,7 11,4 1310 614 378 256 134 96 59
0,8 12,3 1583 734 435 295 155 111 67

 

Panel weights are given according to Type 75 (75 mm insulation thickness).

Find Closest Dealer

Panel Joint Detail

Frequently Asked Questions

Izocam Tekiz Products are available at İZOCAM-TEKİZ dealers. We do not offer direct sales.

Product installations are handled by İZOCAM-TEKİZ Installation Dealers.

Products are produced to order. They are not kept in stock. İzofom Panels are kept in stock by retail sales dealers.

The warranty term is 2 years.

TS825 separates our country into 4 Regions. The Insulation Thickness should be calculated based on the required value of Uceiling and Uwall (Heat Permeability Coefficient).

Tekiz website and catalogues show the spring load-bearing capacity for each span. You may use this table to determine the appropriate sheet thickness.

All colours in the RAL Catalogue are available for production provided that a minimum limit is exceeded. The standard sandwich panel/corrugated sheet colour is RAL9002.

Stone wool panels feature high fire resistance. They minimise insurance premiums. They safeguard your investment and prevent the fire from spreading, ensuring safety of your employees at high-risk facilities.

Fire resistance duration for roof sandwich panels. It means that the sandwich panel can bear load, preserve its integrity and maintain its insulation properties for 120 minutes. The important matter to note here is the availability of these three properties (REI120) concurrently.

R : Load-bearing capacity

E : Integrity

I : Insulation

The Regulation on Fire-Proofing Buildings categorise the flammability classes of building materials in line with the fire-reaction classification established with EN 13501-1 Euroclass.


The flammability classes of building materials are A1, A2, B, C, D, E and F.


Smoke and drip classes of the materials are not provided for the classes A1 and F.


Smoke and drip classes of the materials are always provided for the classes A2, B, C and D. For instance: A2-s1,d0 or C-s3,d2.

The term Broof roof plating, which meets all criteria for “External Fire Performance” without running any tests, is used to define the product that makes up the uppermost layer in the roof composition.


There is no need for Broof to be tested for panels where both surfaces are metal.


İzocam-Tekiz Kombi panel and PIR Fibro panel bear the Broof(t2) certification, which means they are resistant to external spread of fire. The (t2) annotation here means that tests were performed in windy conditions.

Fire resistance duration for facade sandwich panels. It means that the sandwich panel preserve
its integrity and maintain its insulation properties for 60 minutes. The important matter to note here is
the availability of these two properties (EI60) concurrently.
E → Integrity
I → Insulation